Product Parameter | Parameter Description |
JINYING Model | BL-210 |
Product Name | Door Handle Magnetic Lock without the Exit Button |
Fail Safe | Power on to lock |
Holding force | 250KG(600LBS) |
Current Draw | 450mA@12VDC mA 10% 235mA@24VDC mA 10% |
Delay Time | 0,3,5,9 Sec. |
Open door contact | Photo coupler contact |
Lock status sensor | N.C. & N.O. Output (1A@30VDC) |
Indicator | Double-colored LED light |
Demagnetizer design | Instant demagnetizer when power is off. |
Operation temperature | 40 degree (Room temperature 30 ) |
Weight | 3KG (included wrapping) |
Standard Packing | 5pcs |
Carton Weight | 15KG |
Carton Size | 45*24*20 (cm) |
Step 1:
Please stick the sticker on the desired mounting position (Please refer to Fig.1) and drill holes
according to the sticker's indicated positions. Remove the sticker after drilling a hole for wiring.
Step 2:
Remove both sides of the lock's covers A and pull out the B.(Please refer to Fig.2- Fig.4)
Use screws to screw the body lock tight on the appropriate position. Place all covers back in order.
Step 3:
Remove the upper cover (C) of the handle and then the lower cover(C-1) by removing two screws (A-1 B-1) to pull out plate(D).(Please refer to Fig5-Fig6)
Step 4:
Use two attached screws to screw the handle onto the appropriate position of the installation holes when D is pulled out.(Please refer to Fig 7) Do not screw tight as to adjust both handle and body lock positions well by closing the door for several times to make sure both of them are matched. Screw the remaining three screws when they are matched.
Step 5:
Slide plate(P) in when positioning and adjusting screws are tighten. Assemble the handle and its body's back in order.
Installation diagram
Optional plate
Optional EL-250P plate (thickness of 3.6mm) is available to achieve optimum height of both door frame and door leaf when the unit is installed.